Questions with Complete Solutions 100

Questions & answers Sep 5, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

NICET Level 1 ITM Of Water-Based Systems Questions with Complete Solutions 100% Verified Rated A+ 2023/2024 Who is responsible for the inspection, testing, maintenance and impairment of a water based fire protection system? - Correct Answer The Property owner or designated representative Who's responsibility is it to provide accessibility to components of a water based fire protection system? - Correct Answer The property owner or designated representative Who shall correct or repair deficiencies or impairments found during the inspection, test and maintenance required by standard? - Correct Answer The property owner or designated representative Who is qualified to preform the corrections and repairs of a water based fire protection system? - Correct Answer Qualified maintenance personal or a qualified contractor A permanently marked metal or rigid plastic information sign shall be placed at the system control riser supplying an antifreeze loop, dry system, preaction, or auxiliary system control valve? - Correct Answer An Information Sign, Records made during all inspections, tests and maintenance shall be made available to who upon request? - Correct Answer The Authority Having Jurisdiction All records shall be maintained by? - Correct Answer The Property Owner How long should subsequent records be retained? - Correct Answer 1 year, After the testing and reinstallation of plugs and caps for auxiliary drain and test valves, what action is required? - Correct Answer Shall be restored to full operational condition, To avoid false alarms where a supervisory service is provided the alarm receiving facility shall be notified by the property owner or designated representative before? - Correct Answer conducting any test or procedure that could result in the activation of an alarm, Sprinklers shall be inspected when and how? - Correct Answer Shall be inspected from the floor level annually Sprinklers shall not show signs of the following? - Correct Answer leakage; shall be free of corrosion, foreign materials, paint, and physical damage; and shall be installed in the correct orientation 1 / 2

Sprinklers installed installed in concealed spaces such as above ceilings shall what? - Correct Answer Shall not require inspection, Sprinklers installed in areas that are inaccessible for safety considerations due to process operations shall be inspected? - Correct Answer During each scheduled shutdown The supply of spare sprinklers shall be inspected when? - Correct Answer Annually, A spare sprinkler wrench shall be required for what? - Correct Answer Every type of sprinkler, Sprinkler pipe and fittings shall be inspected from where and when? - Correct Answer Annually from from the floor level, Sprinkler Pipe hangers and seismic bracing shall be inspected? - Correct Answer Annually from the floor level Gauges on a wet pipe sprinkler system shall be inspected? - Correct Answer Monthly, Gauges on a dry, preaction system, and deluge systems shall be inspected? - Correct Answer Monthly When the gauge near the compressor is reading higher than the gauge near the dry pipe valve, the air line shall be what? - Correct Answer Taken out of service Waterflow alarm and supervisory alarm devices shall be inspected? - Correct Answer Quarterly The hydraulic design information sign for hydraulically designed systems shall be inspected? - Correct Answer Quarterly The information sign shall be inspected? - Correct Answer Annually, Where sprinklers have been on service for 50 years shall be? - Correct Answer Replaced Sprinklers manufactured prior to 1920 shall be? - Correct Answer Replaced Sprinklers manufactured using fast-response elements that have been in service for 20 years shall be? - Correct Answer Replaced or tested at 10 year intervals Representative samples of solder-type sprinklers with a temperature classification of extra high (325*F) or greater that are exposed to semi continuous to continuous maximum allowable ambient temperature conditions shall be? - Correct Answer Tested at 5 year intervals

  • / 2

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Questions & answers
Added: Sep 5, 2025
Description:

NICET Level 1 ITM Of Water-Based Systems Questions with Complete Solutions 100% Verified Rated A+ Who is responsible for the inspection, testing, maintenance and impairment of a water based fire pr...

Get this document $30.00