RTTT 214-Dosimetry II Last Semester Questions with Complete Solutions (Latest 2025) A patient is treated at a distance of 70 cm SSD with a SDD of 49.8 cm. The source size is 1.5 cm. What is the geometric penumbra at a depth of 7.5 cm?
- 0.65 cm
- 0.83 cm
- 1.20 cm
- 3.26 cm
- 3.83 cm - Correct Answers ✅0.83 cm
- 0.5% greater
- 3% greater
- 10% greater
- 5% less
- 1.5% less - Correct Answers ✅3% greater
A patient is to be treated with 6 MV photons to a sarcoma of the leg, requiring an extended SSD of 130 cm. Compared with the PDD at 100 cm SSD, the PDD at 8 cm depth at 130 cm SSD will be approximately ______ than that at 100 cm SSD.
Which of the following represents the ratio of the dose at a given point in a phantom to the dose in free space at the same point? 1 / 4
RTTT 214-Dosimetry II Last Semester Questions with Complete Solutions (Latest 2025)
- Scatter-air ratio (SAR)
- Off-axis ratio
- Tissue-phantom ratio (TPR)
- Tissue-air ratio (TAR)
- Tissue-maximum ratio (TMR) - Correct Answers ✅Tissue-
air ratio (TAR)
The side of the equivalent square of a 5 x 25 cm field is:
- Approximately equal to the square root of (5x25)
- Closer to 25 than 5
- The square field, which has the same PDD as the rectangle
- Approximated by the (area/perimeter of the rectangle) -
Correct Answers ✅The square field, which has the same PDD as the rectangle A patient was simulated for treatment on a linear accelerator at 100 cm SAD for a 10 cm x 10 cm field but has been scheduled for treatment on a Cobalt-60 at 80 cm SAD. If blocks need to be cut for the Cobalt-60 unit from the 100 cm film that has a target-to-film (TFD/SFD) distance of 150 cm, what TFD should be used? (Assume that the field size does not need to be adjusted) 2 / 4
RTTT 214-Dosimetry II Last Semester Questions with Complete Solutions (Latest 2025)
- 120 cm
- 130 cm
- 150 cm
- 188 cm
- Cannot use the same simulator field, must re-simulate -
- The angle of the 100% isodose line with a line
- The actual measurements of the wedge
- The angle of the 80% isodose line with a line perpendicular
- 2 times the hinge angle - Correct Answers ✅The angle
- times the hinge angle
Correct Answers ✅120 cm What determines the wedge angle?
perpendicular to the central axis
to the central axis
of the 80% isodose line with a line perpendicular to the central axis
As the SSD increase, the PDD:
- Increases 3 / 4
RTTT 214-Dosimetry II Last Semester Questions with Complete Solutions (Latest 2025)
- Decreases
- Remains the same
- There is no effect - Correct Answers ✅Increases
- BEV
- DVH
- DRR
- REV - Correct Answers ✅DVH
Which of the following is a plot of target or normal structure volume as a function of dose?
As the field size increases, the PDD:
- Increase
- Decrease
- Remains the same
- There is no effect - Correct Answers ✅Increase
- / 4
Which of the following accounts for target motion and uncertainty in positioning?