S-95 FDNY TEST STUDY GUIDE QUESTIONS

AND ANSWERS 100% PASS

Question : What Can A S95 Holder do?

CORRECT ANSWER : Only visual inspections on smoke

alarms

Question : Primary Purpose of Fire Alarm Systems

CORRECT ANSWER : on a premise is to warn tenants and

transmit signals indicating a fire condition to the FDNY aka Central station

Question : Fire Alarm Control Panel (FACP)

CORRECT ANSWER : Monitors inputs and controls output

through various types of circuits.The Panel activates the building audible and visual device connected to the fire alarm (horn/strobes)

Question : Three Types of Signals

CORRECT ANSWER : Fire Alarm Signal, Supervisory

Signals, and Trouble Signals

  • | Page

Question : Fire Alarm Signal

CORRECT ANSWER : Manual fire alarm pull station, smoke

detector, water flow switch in the presence of a fire or fire signature.

Question : Supervisory Signals

CORRECT ANSWER : Signals which Indicate that a system or

device being monitored has been compromised or is in an abnormal state. Will audibly and visually annunciate at the FACP to indicate the condition needs to be investigated and corrected. The FACP will also send a signal to an FDNY approved central station.

Question : Trouble Signals

CORRECT ANSWER : Battery failure, AC failure, ground

fault, open or short circuit on a wire, phone line failure, internal component failure.

Question : Alarm Silence Switch or Button

CORRECT ANSW ER: Is used to silence the building audible

and visual devices after evacuation is complete while the source

  • | Page

of alarm is being investigated. Never reset the fire alarm system until the condition is verified by the FDNY personnel.

Question : System Reset Switch Or Button

CORRECT ANSWER : Reset fire alarm system after condition

is cleared. Should return to normal condition after resetting.Often required to clear supervisory conditions, does not clear trouble conditions.

Question : Smoke detectors must be

CORRECT ANSWER : Cleaned once every 6 months. Test for

smoke entry every once a year

Question : Primary Power

CORRECT ANSWER : shall be generated electric power not

exceeding 277/480 volts

Question : Secondary Power Source

CORRECT ANSWER : Batteries shall not be a sub for

connection to the secondary source

  • | Page

Question : Manual Pull Station~Manually pulling handle

CORRECT ANSWER : Return handle to normal position. A

key or other method may be required to reset the station to normal

Question : Smoke, beam, and duct detectors~ Detection of

particles of combustion

CORRECT ANSWER : Smoke detectors will normally reset

when the reset button is pressed at the FACP if the condition activating the detector has been cleared

Question : Heat detectors~ Abnormally high temperature

CORRECT ANSWER : After activation most Fixed

temperature heat detectors will not self restore and will require replacement by a qualified service technician. Rate of rise detectors will normally self- restore after activation.

Question : Water-Flow device~ Flow of water in a sprinkler

system

CORRECT ANSWER : Device should return to normal when

water ceases to flow.

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 2, 2025
Description:

S-95 FDNY TEST STUDY GUIDE QUESTIONS AND ANSWERS 100% PASS Question : What Can A S95 Holder do? CORRECT ANSWER : Only visual inspections on smoke alarms Question : Primary Purpose of Fire Alarm Sys...

Get this document $30.00