S12 sprinkler test, S13 standpipe test, Sprinklers segment 5, S-12 CITYWIDE SPRINKLER SYSTEMS || All Answers Are Correct 100%.fire department connection correct answers normally on exterior of building... FDNY can pump supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water supplies.system control valve correct answers valve controlling flow to water-based fire protection systems.fire command center correct answers Designated room or area in a structure where the status of the fire detection, alarm, and protection systems is displayed and the systems can be manually controlled.Fire pump, automatic standpipe. correct answers A fire pump located at or below street level that supplies the lower 300 feet (91.4 m) of a standpipe system or a combined standpipe and sprinkler system.tags correct answers on closed section valves serving affected areas: area affected, brief description, occupancy classification, c of f number, estimated time until operational Green tag correct answers no impairment found in entire system- main control valve red tag correct answers place on main control valve if FULLY out of service... put sprinkler company name, date of removal from service and anticipated time to operational blue disk correct answers partially out of service- on all fire department connections water storage tank correct answers Collects cooled water OS & Y valve correct answers indicating type of control valve used for fire sprinkler system deluge valve correct answers water supply control valve intended to be operated by actuation of an automatic detection system that is installed in the same area as the discharge devices.

INTENDED USE IS MANUAL AND AUTO

deluge sprinkler system correct answers employing open sprinklers that are attached to a piping system that is connected to a water supply through a valve that is opened by the operation of a detection system installed in the same areas as the sprinklers. WHEN IT OPENS, water flows into the piping system and discharges from all sprinklers attached.Early suppresion fast response sprinklers correct answers fast response sprinkler that is listed for its capability to provide fire suppression of specific high challenge fire hazards 1 / 3

extra large orifice sprinklers correct answers = or > 1 inch less pressure to achieve a given discharge density extended coverage sprinkler correct answers 400 max square feet discharge 20 foot by 20 foot spacing between sprinklers fire pump correct answers a provider of liquid flow and pressure dedicated to fire protection. A fire pump is a part of a fire sprinklers system water supply and can be powered by electric, diesel or steam. connected to public water source or tank. provides higher pressure to sprinkler system Glass bulb sprinkler correct answers operated by heat breaking a glass bulb filled with a non freezing liquid with diameters that vary form 3 mm for quick response to 5 mm for standard response hose valve correct answers valve to additional hose connection hydraulic placard correct answers sign attached to a hydraulically calculated sprinkler system indicating the design density, required gallons per minute and pressure for the system to operate properly hydraulically calculated systems correct answers method of sizing auto sprinkler piping using a prescribed amount of water to be distributed over a specific area.impairment coordinator correct answers in charge of safety during out of service systems intermediate level sprinkler correct answers sprinkler equipped with integral shields to protect the operating elemtn form discharge from sprinklers installed at higher elevations large orifice sprinkler correct answers sprinkler head with orifice size equal or greater than 3/4 and less than 1 inch listed device correct answers A fire protection component that has been tested to perform under parameters specified for its use by a nationally recognized testing agency. Underwriter's Laboratory (UL) and Factory Mutual (FM) are the two most common.Master Pressure Reducing Valve correct answers A pressure reducing valve installed to regulate pressures in an entire fire protection system and/or standpipe system zone.Main Drain correct answers The primary drain connection located on the system riser and also utilized as a flow test connection.Microbiologically Influenced Corrosion (MIC) correct answers Corrosion caused by the presence of microbes in the water supply that over time attack the interior of metallic piping and cause leaks, pitting, and blockages. 2 / 3

Old-Style/Conventional Sprinkler correct answers A sprinkler that directs 40% to 60% of the water initially in a downward direction and is designed to be installed with the deflector in either the upright or pendent position.Pendent Sprinkler correct answers A sprinkler designed to be installed in such a way that the water stream is directed downward against the deflector.Pintle Screws correct answers A visual indicating device required for sprinklers manufactured prior to 1999 identifying small orifice sprinklers and large orifice sprinklers where orifice size is different than the nominal thread size of the sprinkler head.Pipe Schedule Systems correct answers A method of sizing piping based upon the number of sprinkler heads and the occupancy of the protected area.Preaction Sprinkler System correct answers A sprinkler system employing automatic sprinklers that are attached to a piping system that contains air that may or may not be under pressure, with a supplemental detection system installed in the same areas as the sprinklers.Pressure Control Valve correct answers A pilot operated pressure reducing valve that may be used with a fire or booster pump designed for the purpose of preventing the incoming water supply pressure from dropping below a set pressure.Pressure-Reducing Valve correct answers A valve designed for the purpose of reducing the downstream water pressure under both flowing (residual) and nonflowing (static) conditions.Pressure Relief Valve correct answers A valve designed for the purpose of releasing excess air or water pressure from the Fire Protection Piping System.Pressure Tank correct answers A tank using air pressure to supplying water for water-based fire protection systems. Tank contents to be maintained at one third air to two thirds water.Quick Response Sprinkler Head correct answers A sprinkler having a fusible link with a response time index (RTI) of 50 or less.Recessed Sprinkler correct answers A sprinkler in which all or part of the body, other than the shank thread, is mounted above the ceiling.Residential Sprinkler correct answers A type of fast response sprinkler that has been specifically tested to enhance survivability in the room of fire origin and listed for use in dwelling units.Response Time Index (RTI) correct answers A measurement of the thermal sensitivity of a sprinkler head expressed in (meters-seconds) 1/2.Supervisory signal correct answers A signal indicating the need for action or the use of such device in connection with the supervision of fire alarm systems or the maintenance features of related systems.

  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Aug 27, 2025
Description:

S12 sprinkler test, S13 standpipe test, Sprinklers segment 5, S-12 CITYWIDE SPRINKLER SYSTEMS || All Answers Are Correct 100%. fire department connection correct answers normally on exterior of bui...

Get this document $30.00