Spectrum - Field Tech New Hire, Spectrum Field Tech New Hire Week 2 Test Questions with Correct Answers What does the "S" in S.A.F.E stand for? - Correct Answer Stop What does the "A" in S.A.F.E stand for? - Correct Answer Assess What does the "F" in S.A.F.E stand for? - Correct Answer Focus What does the "E" in S.A.F.E stand for? - Correct Answer Eliminate What are the three branches of the Safety Triangle? - Correct Answer Knowledge Technique Attitude What (in electricity) is the direct cause of injury voltage (E), current (I), or resistance (R)? - Correct Answer Current (I) What is the safety rating for glasses? - Correct Answer ANZI 87.1 What are the three main causes of electrical accident? - Correct Answer 1) Unsafe Equipment 2) Work Places 3) Unsafe work practices What are the 2 root causes of safety accidents? - Correct Answer 1) Failure to manage risk 2) Failure to identify real and potential hazards What is Ohm's law equation? - Correct Answer voltage (E) = current (I) x resistance (R) 1 / 2
What is the max reach for a step ladder? - Correct Answer Ladder height + 4 feet What is the max reach for an extension ladder? - Correct Answer Ladder height - 1 foot What is the height:lean ration for ladders? - Correct Answer 4 feet high:1 foot far What are the proper pole inspection steps? - Correct Answer 1)Visual 2)FVD 3)Hammer 4)Prod What does FVD stand for? - Correct Answer Foreign Voltage Detector What colors are used for ground wires? - Correct Answer Green or Green/Yellow What colors are used for hot wires? - Correct Answer Red, Black, or Blue What colors are used for neutral wires? - Correct Answer White or Gray What does GFCI stand for and what does it do? - Correct Answer Ground Fault Circuit Interrupter and it shuts off as quick as 1/40 of a second.What is the most common shock related injury? - Correct Answer A Burn
What is the drop clearance for Power? - Correct Answer Pole: 40"
Mid-Span: 24"
House: 12"
What is the drop clearance for Telephone? - Correct Answer Pole: 12"
- / 2