Tfm03 test Latest Update 2025-2026 100 Questions and 100% Verified Correct Answers Guaranteed A+

2-a rated or a 1.6gal wet chemical fire extinguisher shall have a minimum of - CORRECT ANSWER: 20 ft spray used for solid fuel pile and fule pile not exceed 5 ft

A listed or approved grease duct system that is four stories or less shall be provided for

- CORRECT ANSWER: Solid cooking exhaust systems

A test shall be used on pipe using - CORRECT ANSWER: Nitrogen or dry air not

exceeding normal operating pressure

after a discharge you have to set up system back - CORRECT ANSWER: manualy

Airflow switch or transduction shall open the interlock circuit when the airflow falls -

CORRECT ANSWER: 25 % or 10 % of the listed rating

All appliances of firebox of 0.14 volume or less shall have a - CORRECT ANSWER: 2=A rated water type or wet chemical extinguisher

All ash shall be removed from the chamber - CORRECT ANSWER: At least once a day

All deep fat fryers shall be installed with - CORRECT ANSWER: 16 in space

All ducts shall be installed with a minimum of 2% slope on horizontal runs that -

CORRECT ANSWER: Run up to 75 ft

  • / 2

All ducts shall be installed with a minimum of 8% slope on horizontal runs that -

CORRECT ANSWER: Are greater than 75 feet

All ducts shall be lead directly to - CORRECT ANSWER: Exterior of building to not increase any fire hazard

All ducts shall not be - CORRECT ANSWER: Interconnected with any other building

ventilation system or exhaust system

All seams joint ducts to ducts shall have a - CORRECT ANSWER: Liquidtight

continously external welds

An approved weekly recorded inspection - CORRECT ANSWER: Consists of log entries

Appliance flue outlet opening of cooking device is where - CORRECT ANSWER: Vapors combustion gasses or both leave the cooking decice

Ash removal container cart shall not exceed - CORRECT ANSWER: 20gallons

Baffle plates shall be not less than - CORRECT ANSWER: 6 in from grease removal

device

Baffle plates travel distance - CORRECT ANSWER: 18 in

blow off caps - CORRECT ANSWER: shall alwas be installed upon installation

Bulb type automatic sprinklers and fusible links other than metal alloys shall be replaced

- CORRECT ANSWER: Annually

  • / 2

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 27, 2025
Description:

Tfm03 test Latest Update 2025-2026 100 Questions and 100% Verified Correct Answers Guaranteed A+ 2-a rated or a 1.6gal wet chemical fire extinguisher shall have a minimum of - CORRECT ANSWER: 20 ft...

Get this document $30.00