  • When the required minimum clearance for a vent connector is 9" (228 mm)
  • to combustible material with no protection, what is the acceptable method to reduce the clearance by 3" (76 mm)?

  • Use 0.05" (12 mm) insulating millboard spaced out 0.05" (12 mm) with
  • noncombustible spacers

  • Use 0.25" (6 mm) insulating millboard spaced out 1" (25 mm)
  • Use 22 gauge sheet metal attached to the hot side of the combustible material
  • Use 28 gauge sheet metal spaced out 1" (25 mm) from the combustible
  • material

Correct Answer: B

  • When using a gas detector such as a Drager or Gas Tec type, the most

important aspect regarding the sample tube is that the:

  • Detector is within the manufacturer's date code
  • Sample tube is within the manufacturer's date code
  • Detector has been inspected and verified
  • Sample tube is CGA approved

Correct Answer: B

  • How far above the burner port does the centre line of the flue outlet have to
  • be to convert a revertible flue furnace with a natural draft burner?

  • At least 6" (150 mm)
  • Less than 12" (300 mm)
  • At least 12" (300 mm)
  • At least 24" (600 mm)

Correct Answer: C

4. The vent of a direct vent propane appliance shall not terminate:

  • Within 2 ft. of a property line
  • Less than 3 ft. from a gas service regulator
  • Within 3 ft. of a mechanical air supply inlet to a building
  • Within 10 ft. of a mechanical air supply inlet to a building

Correct Answer: C

  • Which of the following is the best way to increase the furnace blower speed?
  • Open up the motor pulley
  • Close up the motor pulley
  • Install a higher horsepower fan motor
  • Increase the size of the return air duct

Correct Answer: B

6. The baffles in a hot water boiler are designed:

  • To reduce water flow
  • To clean boiler tubes
  • To premix air and gas
  • To slow hot flue gases flow

Correct Answer: D

7. A condensing furnace has:

  • One heat exchanger
  • Operates without a heat exchanger
  • Two heat exchangers
  • Condensate drain and one exchanger

Correct Answer: C

8. Before lighting a burner in a steam boiler, ensure that:

  • There is water in the boiler
  • The temperature controller is set properly
  • The main burner test firing valve is turned on
  • The safety valves are open

Correct Answer: A

9. On seasonal start up, a pool heater should run:

  • Intermittently
  • Continuously for 24 hours
  • Continuously until the thermostat is satisfied
  • One hour on and one hour off until the thermostat is satisfied

Correct Answer: C

10. Steel boilers are generally classified as:

  • Water tube boilers
  • Vapour tube boilers
  • Square sectional boilers
  • Oval sectional boilers

Correct Answer: A

11. Expansion tanks provide a place for:

  • Water to cool before returning to the system and pressure to build so the
  • system will operate properly

  • Hot water to expand so it will be forced through the system and for steam to
  • be trapped

  • Water to travel and allow for pressure fluctuations in the system
  • Condensate to collect before it returns to the boiler and a place for steam to
  • expand in the system

Correct Answer: C

12. A room heater installed in either a sleeping area or public area shall be:

  • Direct vent only
  • Equipped with a regulator
  • Equipped with a fan
  • Equipped with an on/off switch on the wall

Correct Answer: B

  • What type of vent must be used when the vent of a wall furnace will be
  • concealed in a partition wall?

  • B vent
  • L vent
  • BH vent
  • BW vent

Correct Answer: D

14. Single wall vent connectors:

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 5, 2025
Description:

TSSA G2 EXAM GASTECHNICIAN NEWEST COMPLETE 300 QUESTIONS AND CORRECT ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+||BRAND NEW VERSION!! When the required minimum clearance for a vent connector is 9...

Get this document $30.00