URR Mock Test 1 Questions with 100% Verified Correct Answers Which of the following transducers will produce the highest frequency sound waves?
- 6mm element thickness, 2mm/μs propagation speed of the element
- 2mm element thickness, 6mm/μs propagation speed of the element
- 6mm element thickness, 6mm/μs propagation speed of the element
- 2mm element thickness, 2mm/μs propagation speed of the element - Correct Answer 2mm
element thickness, 6mm/μs propagation speed of the element
The narrowest portion of a beam produced by a focused ultrasound transducer is:
- the focal point
- the Fresnel zone
- the Fraunhofer zone
- the first centimeter of the beam that leaves the transducer - Correct Answer the focal point
- 2500kHz
- 500kHz
- 2.5kHz
- 5kHz - Correct Answer 2.5kHz
- high filter settings
- decreased Doppler gain settings
- spectral broadening
- decreased rejection settings - Correct Answer high filter settings
- an annular array can electronically focus the beam
- an annular array can use phasing to electronically steer the beam 1 / 3
If a Doppler system is operating at a PRF of 5000/s what is the maximum Doppler frequency that can be detected?
Why does Doppler tracing not touch the baseline on either side?
Which of the following statements correctly describes annular arrays?
- annular arrays provide the lowest slice thickness resolution
- annular arrays usually contain 30 or more circular elements - Correct Answer an annular array can
- the 1.5D array eliminates the need for a stand-off pad for superficial imaging
- the 1.5D array can produce a trapezoid field of view while the 1D array can only produce a
- the 1.5D array allows for 3D imaging while the 1D array does not
- the 1.5D array allows for variable elevation focus while the 1D array has a fixed elevation focus -
- period
- spatial pulse length
- pulse repetition frequency
- pulse duration - Correct Answer spatial pulse length
- spatial compounding
- electronic focusing
- 3D volume rendering
- panoramic imaging - Correct Answer panoramic imaging
electronically focus the beam Which of the following describes the primary advantage of a 1.5D array over a 1D array?
rectangular field of view
Correct Answer the 1.5D array allows for variable elevation focus while the 1D array has a fixed elevation focus What wave parameter is defined as the wavelength times the number of cycles in the pulse?
You are scanning a thyroid gland with a 5cm wide linear array transducer. You are unable to document the upper and lower poles in the same image to obtain a length measurement of the gland. Which of the following techniques would assist in documenting the entire thyroid gland on a single image?
The average speed of sound in soft tissue is:
- 1580m/s
- 3300m/s
- 1540m/s
- 1540cm/s - Correct Answer 1540m/s 2 / 3
Which of the following is NOT the proper procedure for disinfection of instruments between patients?
- saniwipes or Cidex can be used to disinfect the transducer after each ultrasound exam
- sonographers should wash their hands after each exam, even if gloves were used
- all biopsy needles should be sent out for sterilization after each use
- gel bottles should be sanitized daily using disinfectant cleanser - Correct Answer all biopsy needles
- the color scale should be reduced so that the entire vessel is filled with blue color
- the color scale should be reduced so that the entire vessel is filled with red color
- the red and blue colors indicate that flow is moving in two different directions simultaneously in
- the heel-to-toe method can be used to change the course of the vessel across the image and this
- hematocrit levels do not affect a Doppler evaluation
- decreased blood viscosity
- increased color flow display
- decreased blood flow velocities - Correct Answer decreased blood flow velocities
- centimeter
- micrometer
- decibel
- millisecond - Correct Answer centimeter
- / 3
should be sent out for sterilization after each use Which of the following correctly describes the color displayed on the image?
the vessel
will allow the vessel to accurately display a single color - Correct Answer the heel-to-toe method can be used to change the course of the vessel across the image and this will allow the vessel to accurately display a single color What effect will increased hematocrit levels have on an arterial duplex exam?
When using a tissue phantom to evaluate range accuracy, what unit will be used to report the measurement?
Increasing the angle of electronic steering causes _______ production of lobe artifact