Vivint practice quiz questions with correct answers True or False: The FireFighter may be installed next to a stand-alone battery-powered smoke detector. - Correct Answer False True or False: When performing a full system test, you may bypass any open doors or windows. - Correct Answer False When programming an SKEY1, you must Always...? - Correct Answer Enable emergency key True or False: When running power to the TAKE-345, polarity does not apply. - Correct Answer False When programming the emergency key for an SKEY1, which zone/sensor types are recommended to use? - Correct Answer Auxiliary and audible alarm True or False: When installing an SMKT3, you must use the included screws and anchors - Correct Answer True True or False: When installing the Fire Fighter, it is required to test the customer's existing smoke detectors. - Correct Answer T When installing a DW21, where is the approved location for the sensor? - Correct Answer Btw 6 & 2 in from the floor When installing a DW11 on a vinyl or metal frame, what should you primarily use to mount the sensor? - Correct Answer Double sided tape Select all that apply: Which of the following materials can you use to group multiple ground terminals in a Takeover module? - Correct Answer Wire caps or B connectors/Beans What sensor are you not allowed to program using a translator? - Correct Answer Smoke detector 1 / 2
True or False: When installing the TAKE-345 you must always test the new 12v Battery before using it. - Correct Answer True What is the output voltage of the transformer used to power the Smart Hub? - Correct Answer 12 VDC What is the minimum distance for placement of a CO3 from the corners on a wall? - Correct Answer 12 in True or False: The SMKT3 has only 2 functions: smoke and heat detection. - Correct Answer False How would you program a CO3 if mounted on a hallway wall? - Correct Answer Loop 1, zone type 14 True or False: When installing a translator, you must program all of the existing sensors as new equipment on the panel. - Correct Answer false When programming a DW11 that has been installed on a window, which zone/sensor type should you use? - Correct Answer 3 True or False: The DW21 sensor should always be installed in the door frame - Correct Answer True What equipment is used on all metal door frames - Correct Answer DW11 Which zone/sensor types are used when programming an SMKT3? - Correct Answer Type 9 smoke detection, type 8 freeze detection, type 9 heat detection What is the correct height at which to install the PIR2? - Correct Answer 7.5 ft When programming a DW21, which loop number is used? - Correct Answer 1 True or False: When programming a sensor into the panel, you can type in the serial number or "learn" it in by triggering the device. - Correct Answer True
- / 2