Vivint Smart Home Pro Final Exam Questions and 100% Verified Correct Answers 2024 What is the input voltage range of the Doorbell Cam? - Correct Answer 12-24v What is the output voltage of the transformer used to power the SkyControl panel? - Correct Answer 16.5 VAC True or False: When programming a sensor into the sky panel you can type in the serial number or "learn" it in by triggering the device - Correct Answer true When programming a DW21, which loop number is used?1 2
- - Correct Answer 2
Which of the following materials can you use to group multiple ground terminals in a
takeover module:
Solder String Wire Caps Duct Tape Beans - Correct Answer beans and wire caps T or F: When installing the firefighter, it is required to test the customer's existing smoke detectors - Correct Answer True When installing a DW21, what size bit should you use to drill the hole for the sensor?1/2" 3/8" 3/4" 1" - Correct Answer 3/4"
T or F: When installing the TAKE-345, you must ensure that the transformer is
supplying power to the power supply before the battery. - Correct Answer True T or F: You are required to test signals from all secondary keypads and key fobs even though they are not detection devices - Correct Answer True T or F: When running power to the TAKE-345 polarity does not apply - Correct Answer False What is the correct height at which to install the PIR2?
- ft
At least 5 ft At least 7 ft 1 / 2
At 7.5 ft - Correct Answer
- Correct Answer How would you program a CO3 if mounted on a hallway wall?
- Correct Answer When installing a DW21 into a metal door frame, with a wooden door,
Loop 1 Zone 8 Loop 1 Zone 14 Loop 3 Zone 4 Loop 1 Zone 4
what should you be sure to use?Metal Drill bit A DW11 should be used on all metal door frames 3/4" insulated magnet Eye goggles
T or F: Panic Pendants are programmed as an audible alarm - Correct Answer True
- Correct Answer T or F: The Firefighter may be installed next to a stand-alone battery-
- Correct Answer Which of the following zone/sensor types are correct when
- Correct Answer When installing a DW21 where is the approved location for the
- Correct Answer T or F: When performing a full system test, you may bypass any open
- Correct Answer T or F: When installing a translator, you must program all of the
- / 2
powered smoke detector
programming an SMKT3?Type 9 - Freeze Detect Type 7 - Freeze Detect Type 9 - Heat detect Type 6 - heat detect type 1 - heat detect type 8 - freeze detect type 5 - smoke detect type 7 - smoke detect type 9 - smoke detect
sensor?Anywhere in the door between 6"(15 cm) and 2' (61 cm) from floor Below 6" from the floor Top of the door
doors or windows
existing sensors as new equipment on the panel