- | P a g e
ARIZONA PLUMBING RC -37 LATEST
PRACTICE EXAM QUESTIONS AND
ANSWERS
Question 1: What minimum pressure is required to test a drainage system with
air?
- 3 psi
- 5 psi
- 10 psi
- 15 psi
Correct Answer: B) 5 psi
Question 2: What maximum fixture unit load is allowed on 2 inch trap?
- 2 fu
- 3 fu
- 4 fu
- 6 fu
Correct Answer: B) 3 fu
Question 3: Refer to the illustration. Given: This one inch pipe offset uses 45 degree elbows and an offset distance of 8 inches at "B". What is the center to center length of the diagonal "A"?
- 10-1/2 inches
- 11-1/8 inches
- 11-5/16 inches
- | P a g e
- 12-1/4 inches
Correct Answer: C) 11-5/16 inches
Question 4: Which of the following is NOT required to calculate water pipe
sizes?
- Total developed length of pipe
- Maximum street pressure
- Number of fixture units
- Minimum daily temperature
Correct Answer: B) Maximum street pressure
Question 5: Which of the following backflow prevention devices protects
against back pressure?
- Atmospheric vacuum breaker
- Air gap
- Double check-valve assembly
- Pressure vacuum breaker
Correct Answer: C) Double check-valve assembly
Question 6: What is the name of the device in a hot water heating system that
allows trapped air to escape from the system?
- Air vent
- Relief valve
- Expansion tank
- Check valve
Correct Answer: A) Air vent
- | P a g e
Question 7: Given: A low hazard boiler system does not require chemical additives, but has the potential to cause back pressure. What minimum back flow protection is required for the water make up supply?
- Atmospheric vacuum breaker
- Double check valve with intermediate vent
- Reduced pressure zone assembly
- Simple check valve
Correct Answer: B) Double check valve with intermediate vent
Question 8: What is required for materials that are used in medical gas piping
systems?
- Delivered to job site cleaned and capped
- Painted with green identifying bands
- Flushed with chlorine before use
- Sterilized with ultraviolet light
Correct Answer: A) Delivered to job site cleaned and capped
Question 9: What is the purpose of an expansion tank?
- It increases water pressure in the system
- It allows for expanded water volume after heating
- It stores excess cold water
- It traps air to prevent water hammer
Correct Answer: B) It allows for expanded water volume after heating
Question 10: What minimum separation is required between a residential septic
tank disposal field and a domestic service water line?
- 3 feet
- | P a g e
- 5 feet
- 10 feet
- 15 feet
Correct Answer: B) 5 feet
Question 11: Given: A water service pipe is to be installed in a trench with a sewer pipe. What minimum vertical distance is required between the bottom of the water service pipe and the top of the sewer pipe?
- 6 inches
- 12 inches
- 18 inches
- 24 inches
Correct Answer: B) 12 inches
Question 12: What is the name for the exterior drainage pipe that carries storm
water from roof drain systems?
- Conductor
- Leader
- Downspout
- Riser
Correct Answer: B) Leader
Question 13: What maximum percent of lead content is permitted in solder used
for a copper water pipe system?