- | P a g e
CT REGISTRY LATEST
REVIEW WITH COMPLETE
SOLUTION COMPLETE
AND VERIFIED STUDY
MATERIAL
Question 1: Xrays are used in CT because:
- they are easily produced by the high frequency generator
- they are less harmful than the heating effects of microwave radiation
- they penetrate the body according to specific attenuation characteristics of each tissue
- the FDA imposes no limit on the dose to the patient
Correct Answer: C
Question 2: Most of the commands from the technologists are received by the:
- array processor
- host computer
- operators console
- gantry
Correct Answer: C) operators console
- | P a g e
Question 3: Xrays are produced whenever fast moving electrons collide with any form of matter
because:
- The electron loses kinetic energy which is converted into the emission of an x-ray photon
- The electron absorbs thermal energy and reflects it as a photon
- The matter converts its potential energy into radiation
- The collision generates an electrical charge within the detector
Correct Answer: A) The electron loses kinetic energy which is converted into the emission of an x-ray photon
Question 4: The mA determines the:
- quality of x-ray photons
- quantity of x-ray photons
- spatial resolution of the image
- speed of the tube rotation
Correct Answer: B) quantity of x-ray photons
Question 5: Which of the following is a component NOT normally located in the gantry of a modern CT system?
- x-ray tube
- slip rings
- array processor
- solid-state detectors
Correct Answer: C) array processor
Question 6: Tube interscan delay time refers to:
- the time required for the patient table to move into position
- | P a g e
- the time between the end of one scan and the start of the next scan during which the tube will
- the time it takes for the array processor to reconstruct the image
- the delay before contrast media is injected
cool
Correct Answer: B) the time between the end of one scan and the start of the next scan during which the tube will cool
Question 7: Increased _______ will increase the likelihood that a given x-ray will penetrate a material.
- kV
- mA
- exposure time
- pitch
Correct Answer: A) kV
Question 8: Which of the following are NOT commonly used on today's commercially available CT scanners? 1. xenon detectors 2. fourth-generation technology 3. continuous rotation technology
- 1 only
- 1 and 2
- 2 and 3
- 1, 2, and 3
Correct Answer: B) 1 and 2
Question 9: Which of the following statements is FALSE regarding occurrences after an x-ray photon penetrates the detector aperture?
- the photon can pass through the detector unmeasured
- the photon is converted completely into an electron
- | P a g e
- the measured signal is enhanced by an amplifier
- the photon can be absorbed by the detector material
Correct Answer: B) the photon is converted completely into an electron
Question 10: Scatter radiation is caused by:
- inadequate cooling of the x-ray tube
- deflections from the original trajectory of an x-ray photon through the patient
- electrical interference in the array processor
- improper calibration of the solid-state detectors
Correct Answer: B) deflections from the original trajectory of an x-ray photon through the patient
Question 11: What control does the operator have over the x-rays in a CT exam?
- the energy level and the quantity of x-rays can be selected
- the speed of the x-ray photons can be altered
- the direction of the scatter radiation can be focused
- the operator has no control over the x-ray production
Correct Answer: A) the energy level and the quantity of x-rays can be selected
Question 12: Which of the following is the standard that's used to achieve compatibility for image transfer between various imaging modalities, viewing stations, and printers in a hospital?