Level 1 Water Distribution Practice Test

Study Guides
Loading...

Loading study material viewer...

Page 0 of 0

Document Text

Level 1 Water Distribution Practice Test Questions and Answers 100% Correct

Question : The minimum and maximum chloride residual in a

water distribution system is ?

Correct answer: 0.2 mg/l and 4mg/L of free chlorine

Question : Nitrate may not exceed what concentration when

tested yearly for a groundwater treatment plant ?

Correct answer: 10 mg/L

Question : The minimum number of total coliform samples

that must be collected per month is based on Wich of the following ?

Correct answer: The population served by the system

Question : When a distribution bacteriological sample is

positive for a total coliform the procedure is ?

Correct answer: Repeat the sample and take a sample 5

connections upstream and downstream to confirm total coliform

Question : For lead and copper sample the water must be In

the pipeline for at least?

Correct answer: 6 hours

Question : What is hydraulic grade line ?

Correct answer: A line to which the water level would rise in

a small ,vertical tube,connected to the pipe

Question : How often should cathodic protection anodes in

your system be inspected?

Correct answer: Every year

Question : Water pipelines are generally designed to carry

water at a velocity below ?

Correct answer: 2.5b FPS. Feet per second

Question : Energy use in water systems is defined best by ?

Correct answer: Energy use varies among systems and an

energy inventory study would need to be conducted to determine relationships

Question : The minimum recommended separation distance

between a water main and a storm sewer is ?

Correct answer: 6 feet

Question : Which of the following should be in an

organization plan ?

Correct answer: Identifies clear lines ,defines the divisions of

labor ,establishes unity of command

Question : If pipelines are not restrained using steel rods

concrete thrust blocks can be used at ?

Correct answer: Every bend and transition

Question : Engineering Drawings that show the depth of pipe,

the pipe location both vertically and horizontally and the correct distance form a reference point are known as which of the following

Correct answer: Plan and profile drawings

Question : Which are the components of directing staff ?

Correct answer: Motivating & communicating

Question : The accuracy of large meters should fall within

what range ?

Correct answer: Not less than 97% not more than 103%

Question : In some older water system lead service line still

exist. What would be the best practice when finding lead pipe ?

Correct answer: Be replaced

Question : What is the acceptable range for water loss in a

typical municipal distribution system that has a variety of pvc and di pipe ?

Correct answer: 20% (80% effienciency)

Download Study Material

Buy This Study Material

$30.00
Buy Now
  • Immediate download after payment
  • Available in the pdf format
  • 100% satisfaction guarantee

Study Material Information

Category: Study Guides
Description:

Level 1 Water Distribution Practice Test Questions and Answers 100% Correct Question : The minimum and maximum chloride residual in a water distribution system is ? Correct answer: 0.2 mg/l and 4mg...

Purchase PDF $30.00